Basic Info.
Model NO.
Copper Conductor/XLPE Insulation/PE Sheath
Application
Construction, Industrial, Power Station
Material Shape
Round Wire
Wire Core Material
Bare Copper Wire
Model
Copper Conductor/XLPE Insulation/PE Sheath
Class of Conductor
Solid or Stranded
Product Description
1,APPLICATION
YJY-Copper Conductor XLPE Insulated PE Sheathed Power Cable
This product is suitable for using in power distribution networks or fixed installations for industrial equipments with rated voltage up to and including 0.6/1KV
2,BASIC INFORMATION
Code Name
YJY
Rated Voltage (Uo/U)
0.6/1KV
Cable Structure
Copper Conductor/XLPE Insulation/PE Sheath
3,,CONSTRUCTION
Conductor
Number of conductors:1,2,3,4,5,3+1,4+1
The conductors shall comply with the requirement given in IEC
Insulation
XLPE(Cross-linked Polyethylene) according to IEC
Sheath
PE(Polyethylene) according to IEC
4,CABLE STANDARDS
GB/T12706-2008,IEC,BS,ASTM and etc. upon request.
5,CHARACTERISTICS
Conductor temperature
Maximum conductor temperature in normal use: 90ºC
Max.short-circuit temperature
Maximum shall not exceed 250ºC(5s Max,Duration)
Installation temperature
Ambient temperature under installation shall not be below 0ºC
Minimum bending radius
The bending radius of cable: (D-Diameter of cable)
-------------------------------------≥15D
6,Voltage designation
The rated voltage of the cable for a given application shall be suitable for the operating conditions in the system in which the cable is used,and is expressed in the form of Uo/ U(Um)kV.
Where:
Uo-The rated power-frequency voltage between conductor and screen or metallic-sheath,for which the cable designed;
U-The rated power-frequency voltage between conductors, for which the cable designed:
Urn-The maximum value of the "hight system voltage " for which the equipment may he operated.
7,Rated voltaged of cable applied in three phrase system are given in table
U | Um | Uo |
First class | Second class |
1 | 1.2 | 0.6 | 0.6 |
3 | 3.6 | 1.8 | 3.6 |
6 | 7.2 | 3.6 | 6 |
10 | 12 | 6 | 8.7 |
15 | 17.5 | 8.7 | 12 |
20 | 24 | 12 | 18 |
35 | 42 | 21 | 26 |
Note:The first class cable suitable for one single-phrase earth-fault time does not exceed 1 min each time and Max. time not exceed 8 hours.and not exceed 125 hours in all in one year.
The second class cable suitable fir more earth-fault time and more better insulation performance.
8,Production Range of cable
Type | No. of cores | Nominal Cross sectional area m2 |
Copper conductor |
YJY | 1* | 1.5-800 |
2 | 1.5-400 |
3 | 1.5-630 |
4 | 1.5-500 |
3+1 | 1.5-630 |
5 | 1.5-500 |
4+1 | 1.5-500 |
3+2 | 1.5-500 |
*The armoured single-core cables are used for D.C system only. As for A.C system non-magnetic armoured material should be used. Or magnetic isolation measures should be applied. |
DIMENSIONS-YJY-Table01
Nominal cross sectional area of conductor(mm²) | Nominal insulation thickness(mm) | 0.6/1KV YJY |
Approx overall diameter(mm) | Cable weight max(kg/km) |
1x1.5 | 0.7 | 5.6 | 52 |
1x2.5 | 0.7 | 6.0 | 65 |
1×4 | 0.7 | 6.4 | 83 |
1×6 | 0.7 | 7.0 | 106 |
1×10 | 0.7 | 8.3 | 157 |
1×16 | 0.7 | 9.3 | 221 |
1×25 | 0.9 | 11.2 | 334 |
1×35 | 0.9 | 12.4 | 435 |
1×50* | 1.0 | 14.1 | 576 |
1×70* | 1.1 | 16.1 | 793 |
1×95* | 1.1 | 18.2 | 1066 |
1×120* | 1.2 | 18.7 | 1275 |
1×150* | 1.4 | 20.7 | 154 |
1×185* | 1.6 | 22.6 | 1868 |
1×240* | 1.7 | 25.1 | 2399 |
1×300* | 1.8 | 27.5 | 3028 |
1×400* | 2.0 | 30.9 | 3888 |
1×500* | 2.2 | 34.5 | 4953 |
1×630* | 2.4 | 38.5 | 6164 |
1×800* | 2.8 | 46.0 | 7909 |
*Compacted conductor
DIMENSIONS-YJY-Table 02
Nominal cross sectional area of conductor(mm²) | Nominal insulation thickness(mm) | 0.6/1KV YJY |
Approx overall diameter(mm) | Cable weight max(kg/km) |
Circular | Sector |
2x1.5 | 0.7 | 9.7 | - | 99 |
2x2.5 | 0.7 | 10.5 | - | 127 |
2×4 | 0.7 | 11.5 | - | 164 |
2×6 | 0.7 | 12.5 | - | 214 |
2×10 | 0.7 | 14.8 | - | 324 |
2×16 | 0.7 | 16.8 | - | 460 |
2×25 | 0.9 | 20.4 | - | 691 |
2×35 | 0.9 | 22.6 | - | 907 |
2×50* | 1.0 | 24.6 | 22.4 | 1039 |
2×70* | 1.1 | 28.6 | 25.0 | 1456 |
2×95* | 1.1 | 32.2 | 29.8 | 1973 |
2×120* | 1.2 | 35.6 | 31.4 | 2459 |
2×150* | 1.4 | 39.4 | 35.6 | 3398 |
2×185* | 1.6 | 43.8 | 38.8 | 4042 |
2×240* | 1.7 | 49.6 | - | 5264 |
2×300* | 1.8 | 54.8 | - | 7345 |
* Compacted conductor
DIMENSIONS-YJY-Table 03
Nominal cross sectional area of conductor(mm²) | Nominal insulation thickness(mm) | 0.6/1KV YJY |
Approx overall diameter(mm) | Cable weight max(kg/km) |
Circular | Sector |
3x1.5 | 0.7 | 10.2 | - | 120 |
3x2.5 | 0.7 | 11.0 | - | 158 |
3×4 | 0.7 | 12.0 | - | 210 |
3×6 | 0.7 | 13.1 | - | 280 |
3×10 | 0.7 | 15.6 | - | 430 |
3×16 | 0.7 | 17.8 | - | 623 |
3×25 | 0.9 | 21.7 | - | 947 |
3×35 | 0.9 | 24.1 | - | 1254 |
3×50* | 1.0 | 26.2 | 28.6 | 1518 |
3×70* | 1.1 | 30.8 | 32.8 | 2143 |
3×95* | 1.1 | 35.0 | 37.0 | 2897 |
3×120* | 1.2 | 38.7 | 40.6 | 3834 |
3×150* | 1.4 | 43.0 | 45.1 | 4827 |
3×185* | 1.6 | 47.7 | 49.6 | 5747 |
3×240* | 1.7 | 53.3 | 54.2 | 7448 |
3×300* | 1.8 | 59.1 | 59.2 | 9463 |
3×400* | 2.0 | 66.4 | 66.0 | 12225 |
*Compacted conductor
DIMENSIONS-YJY-Table 04
Nominal cross sectional area of conductor(mm²) | Nominal insulation thickness(mm) | 0.6/1KV YJY |
Approx overall diameter(mm) | Cable weight max(kg/km) |
Circular | Sector |
4x1.5 | 0.7 | 10.9 | - | 145 |
4x2.5 | 0.7 | 11.8 | - | 194 |
4×4 | 0.7 | 13.0 | - | 261 |
4×6 | 0.7 | 14.2 | - | 352 |
4×10 | 0.7 | 12.0 | - | 547 |
4×16 | 0.7 | 19.4 | - | 799 |
4×25 | 0.9 | 23.8 | - | 1222 |
4×35 | 0.9 | 26.5 | - | 1626 |
4×50* | 1.0 | 29.1 | 28.0 | 2005 |
4×70* | 1.1 | 34.1 | 32.0 | 2855 |
4×95* | 1.1 | 38.8 | 37.5 | 3843 |
4×120* | 1.2 | 43.1 | 40.2 | 5052 |
4×150* | 1.4 | 47.6 | 44.0 | 6336 |
4×185* | 1.6 | 53.1 | 50.8 | 7569 |
4×240* | 1.7 | 59.3 | 56.8 | 9809 |
4×300* | 1.8 | 65.8 | 62.0 | 12467 |
4×400* | 2.0 | 73.9 | 69.7 | 16139 |
*Compacted conductor
DIMENSIONS-YJY-Table 05
Nominal cross sectional area of conductor(mm²) | Nominal insulation thickness(mm) | 0.6/1KV YJY |
Approx overall diameter(mm) | Cable weight max(kg/km) |
Circular | Tile Shape |
5x1.5 | 0.7 | 11.7 | - | 171 |
5x2.5 | 0.7 | 12.7 | - | 231 |
5×4 | 0.7 | 14.0 | - | 314 |
5×6 | 0.7 | 15.4 | - | 426 |
5×10 | 0.7 | 18.5 | - | 666 |
5×16 | 0.7 | 21.2 | - | 978 |
5×25 | 0.9 | 26.1 | - | 1503 |
5×35 | 0.9 | 29.0 | - | 2004 |
5×50* | 1.0 | 32.7 | - | 2605 |
5×70* | 1.1 | 38.3 | 35.8 | 3617 |
5×95* | 1.1 | 43.1 | 40.6 | 5006 |
5×120* | 1.2 | 47.6 | 44.0 | 6276 |
5×150* | 1.4 | 52.8 | 49.0 | 7897 |
5×185* | 1.6 | 58.9 | 54.2 | 9297 |
5×240* | 1.7 | 65.8 | 61.9 | 12220 |
5×300* | 1.8 | 72.9 | 67.2 | 15530 |
5×400* | 2.0 | 82.12 | - | 20143 |
*Compacted conductor
DIMENSIONS-YJY-Table 06
Nominal cross sectional area of conductor(mm²) | No.of cores | Nominal insulation thickness(mm) | 0.6/1KV YJY |
Approx overall diameter(mm) | Cable weight max(kg/km) |
Circular | Sector |
3x1.5+1x1 | 3 | 0.7 | 10.9 | - | 138 |
1 | 0.7 |
3x2.5+1x1.5 | 3 | 0.7 | 11.6 | - | 181 |
1 | 0.7 |
3x4+1x2.5 | 3 | 0.7 | 12.7 | - | 245 |
1 | 0.7 |
3x6+1x4 | 3 | 0.7 | 13.9 | - | 329 |
1 | 0.7 |
3x10+1x6 | 3 | 0.7 | 16.3 | - | 497 |
1 | 0.7 |
3x16+1x10 | 3 | 0.7 | 18.8 | - | 734 |
1 | 0.7 |
3x25+1x16 | 3 | 0.9 | 22.7 | - | 1114 |
1 | 0.7 |
3x35+1x16 | 3 | 0.9 | 24.7 | - | 1414 |
1 | 0.7 |
3x50+1x25 | 3* | 1.0 | 27.6 | 28.8 | 1807 |
1 | 0.9 |
3x70+1x35 | 3* | 1.1 | 32.1 | 32.8 | 2559 |
1 | 0.9 |
*Compacted conductor
DIMENSIONS-YJY-Table 06
Nominal cross sectional area of conductor(mm²) | No.of cores | Nominal insulation thickness(mm) | 0.6/1KV YJY |
Approx overall diameter(mm) | Cable weight max(kg/km) |
Circular | Sector |
3x95+1x50 | 3* | 1.1 | 36.6 | 38.5 | 3450 |
1 | 1.0 |
3x120+1x70 | 3* | 1.2 | 40.9 | 41.0 | 4502 |
1 | 1.1 |
3x150+1x70 | 3* | 1.4 | 44.3 | 44.8 | 5460 |
1 | 1.1 |
3x185+1x95 | 3* | 1.6 | 49.6 | 51.6 | 6658 |
1 | 1.1 |
3x240+1x120 | 3* | 1.7 | 55.3 | 57.7 | 8591 |
1 | 1.2 |
3x300+1x150 | 3* | 1.8 | 61.3 | 62.8 | 10906 |
1 | 1.4 |
3x400+1x185 | 3* | 2.0 | 68.6 | 70.3 | 13938 |
1 | 1.6 |
*Compacted conductor
DIMENSIONS-YJY-Table 07-A
Nominal cross sectional area of conductor(mm²) | No.of cores | Nominal insulation thickness(mm) | 0.6/1KV YJY |
Approx overall diameter(mm) | Cable weight max(kg/km) |
Circular | Tile Shape |
4x1.5+1x1 | 4 | 0.7 | 11.8 | - | 165 |
1 | 0.7 |
4x2.5+1x1.5 | 4 | 0.7 | 12.5 | - | 219 |
1 | 0.7 |
4x4+1x2.5 | 4 | 0.7 | 13.7 | - | 297 |
1 | 0.7 |
4x6+1x4 | 4 | 0.7 | 15.1 | - | 403 |
1 | 0.7 |
4x10+1x6 | 4 | 0.7 | 17.9 | - | 617 |
1 | 0.7 |
4x16+1x10 | 4 | 0.7 | 20.7 | - | 915 |
1 | 0.7 |
4x25+1x16 | 4 | 0.9 | 25.1 | - | 1397 |
1 | 0.7 |
4x35+1x16 | 4 | 0.9 | 27.5 | - | 1796 |
1 | 0.7 |
4x50+1x25 | 4* | 1.0 | 31.4 | - | 2371 |
1 | 0.9 |
4x70+1x35 | 4* | 1.1 | 36.7 | 34.0 | 3287 |
1 | 0.9 |
4x95+1x50 | 4* | 1.1 | 40.8 | 38.8 | 4515 |
1 | 1.0 |
*Compacted conductor
DIMENSIONS-YJY-Table 07-B
Nominal cross sectional area of conductor(mm²) | No.of cores | Nominal insulation thickness(mm) | 0.6/1KV YJY |
Approx overall diameter(mm) | Cable weight max(kg/km) |
Circular | Tile Shape |
4x150+1x70 | 4* | 1.4 | 50.0 | 46.6 | 7025 |
1 | 1.1 |
4x185+1x95 | 4* | 1.6 | 55.7 | 51.8 | 8525 |
1 | 1.1 |
4x240+1x120 | 4* | 1.7 | 62.1 | 57.8 | 11008 |
1 | 1.2 |
4x300+1x150 | 4* | 1.8 | 69.8 | 63.8 | 13978 |
1 | 1.4 |
4x400+1x185 | 4* | 2.0 | 77.4 | - | 17941 |
1 | 1.6 |
*Compacted conductor
DIMENSIONS-YJY-Table 08
Nominal cross sectional area of conductor(mm²) | No.of cores | Nominal insulation thickness(mm) | 0.6/1KV YJY |
Approx overall diameter(mm) | Cable weight max(kg/km) |
Circular | Tile Shape |
3x1.5+2x1 | 3 | 0.7 | 11.4 | - | 158 |
2 | 0.7 |
3x2.5+2x1.5 | 3 | 0.7 | 12.4 | - | 207 |
2 | 0.7 |
3x4+2x2.5 | 3 | 0.7 | 13.5 | - | 282 |
2 | 0.7 |
3x6+2x4 | 3 | 0.7 | 14.9 | - | 382 |
2 | 0.7 |
3x10+2x6 | 3 | 0.7 | 17.3 | - | 569 |
2 | 0.7 |
3x16+2x10 | 3 | 0.7 | 20.1 | - | 853 |
2 | 0.7 |
3x25+2x16 | 3 | 0.9 | 24.1 | - | 1292 |
2 | 0.7 |
3x35+2x16 | 3 | 0.9 | 25.9 | - | 1590 |
2 | 0.7 |
3x50+2x25 | 3* | 1.0 | 30.3 | - | 2127 |
2 | 0.9 |
3x70+2x35 | 3* | 1.1 | 34.9 | 33.8 | 2943 |
2 | 0.9 |
3x95+2x50 | 3* | 1.1 | 39.0 | 38.8 | 4043 |
2 | 1.0 |
3x120+2x70 | 3* | 1.2 | 43.9 | 42.4 | 5207 |
2 | 1.1 |
3x150+2x70 | 3* | 1.4 | 47.0 | 46.4 | 6161 |
2 | 1.1 |
3x185+2x95 | 3* | 1.6 | 52.6 | 51.6 | 7628 |
2 | 1.1 |
*Compacted conductor
DIMENSIONS-YJY-Table 08
Nominal cross sectional area of conductor(mm²) | No.of cores | Nominal insulation thickness(mm) | 0.6/1KV YJY |
Approx overall diameter(mm) | Cable weight max(kg/km) |
Circular | Tile Shape |
3x240+2x120 | 3* | 1.7 | 58.5 | 57.6 | 9808 |
2 | 1.2 |
3x300+2x150 | 3* | 1.8 | 64.9 | 63.6 | 12438 |
2 | 1.4 |
3x4006+2x185 | 3* | 2.0 | 72.7 | - | 15769 |
2 | 1.6 |
10,Product Data Of Cable
Nominal cross-sectional area of conductor(mm²) | Max.D.C resistance of conductor at 20ºC(Ω/km) |
Copper |
1 | 18.1 |
1.5 | 12.1 |
2.5 | 7.41 |
4 | 4.61 |
6 | 3.08 |
10 | 1.83 |
16 | 1.15 |
25 | 0.727 |
35 | 0.524 |
50 | 0.387 |
70 | 0.268 |
95 | 0.193 |
120 | 0.153 |
150 | 0.124 |
185 | 0.0991 |
240 | 0.0754 |
300 | 0.0601 |
400 | 0.0470 |
500 | 0.0366 |
630 | 0.0283 |
800 | 0.0021 |
Power frequency A.C. Voltage test | Test voltage 3.5kV/5 min |
11,Current carrying capacity of cable
l In the air
Conductor | Nominal Cross sectional area of conductor mm2 | Unarmoured cable |
Single Core | Two Core | Three cores & Five cores |
| |
Copper Conductor | 1.5 | 21 | 24 | 18 | 16 |
2.5 | 31 | 41 | 33 | 28 |
4 | 41 | 54 | 43 | 37 |
6 | 52 | 68 | 55 | 47 |
10 | 71 | 93 | 76 | 65 |
16 | 92 | 120 | 97 | 84 |
25 | 120 | 155 | 130 | 110 |
35 | 150 | 195 | 160 | 135 |
50 | 180 | 235 | 195 | 170 |
70 | 230 | 295 | 245 | 215 |
95 | 285 | 370 | 305 | 265 |
120 | 335 | 430 | 355 | 310 |
150 | 385 | 495 | 405 | 350 |
185 | 450 | 570 | 465 | 405 |
240 | 535 | 680 | 525 | 480 |
300 | 620 | 790 | 620 | 555 |
400 | 720 | 920 | - | 640 |
500 | 835 | 1080 | - | - |
630 | 960 | 1260 | - | - |
800 | 1110 | 1470 | - | - |
12,Current carrying capacity of cable
l In the ground
Conductor | Nominal Cross sectional area of conductor mm2 | Unarmoured cable |
Single Core | Two Core | Three cores & Five cores |
| |
Copper Conductor | 1.5 | 25 | 28 | 27 | 23 |
2.5 | 42 | 46 | 46 | 39 |
4 | 55 | 59 | 59 | 51 |
6 | 69 | 74 | 75 | 64 |
10 | 92 | 98 | 100 | 86 |
16 | 115 | 125 | 130 | 110 |
25 | 150 | 160 | 165 | 140 |
35 | 180 | 190 | 200 | 170 |
50 | 215 | 230 | 240 | 205 |
70 | 265 | 280 | 290 | 250 |
95 | 320 | 335 | 355 | 300 |
120 | 360 | 385 | 405 | 345 |
150 | 410 | 430 | 450 | 385 |
185 | 460 | 490 | 510 | 435 |
240 | 535 | 570 | - | 500 |
300 | 605 | 645 | - | 565 |
400 | 685 | 735 | - | 640 |
500 | 775 | 840 | - | - |
630 | 865 | 950 | - | - |
800 | 960 | 1080 | - | - |
13,Installation and Operation Condition of Cable
l
In the air
1.The distance between two adjacent cable' axle centers of single-core cables laid in parallel cross-section area of conductor≤185mm²;2 times of the cable diameter cross-sectional area of conductor≥240mm²;90mm
2.Ambient air temperature:30ºC.
3.Max.continous operating temperature of conductor: 90ºC.
l
Current carrying rating factors for different ambient air temperature
Ambient air temperature | 20ºC | 25ºC | 30ºC | 35ºC | 40ºC | 45ºC |
Correction factor | 1.09 | 1.04 | 1.00 | 0.95 | 0.90 | 0.84 |
l
Directly in the ground
1.The single-core cables are installed separately.The distance between the cable
center is 2 times of the cable Diameter.
2.Soil temperature: 25ºC.
3.Max.continous operating temperature of
conductor: 90ºC.
4.Thermal resistivity of soil : 1.0 ºC. m/W
5.Depth of Direct-Buried:0.7m.
l
Current carrying rating factors for different soil temperature
Soil temperature | 20ºC | 25ºC | 30ºC | 35ºC | 40ºC |
Correction factor | 1.04 | 1.0 | 0.96 | 0.92 | 0.87 |
Address:
Room1116, Floor 11, Hongxing Jiuzhou International Plaza, Xincheng Road, Yixing, Wuxi, Jiangsu, China
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Chemicals, Electrical & Electronics, Service
Management System Certification:
ISO 9001, ISO 9000, ISO 14001, ISO 14000, ISO 20000, OHSAS/ OHSMS 18001
Company Introduction:
Established in 2014 and bringing together the factory more than 30 years of experience in cable, Lonheo is backed by the excellent reputation of our cooperated factory, All what we do is to make them as leading cable contractors in the world.
Lonheo is able to strive in today′s competitive business environment by creating synergy and consolidating the resources of all partners. This ensures that Lonheo remains operationally and financially strong.
With this strategic partnership in place, Lonheo is able to help our customers achieve their goals and provide greater value-added services to them.
Our company are focus on cable & wire supplyment and waste water treatment chemicals.
Our Features Product:
===Power Cables===
Ultra High Voltage, Power Cable, High Voltage Power Cable, Medium Voltage Power Cable, Low Voltage Power Cable, LSZH (low smoke zero halogen) Cable, XLPE Cable, AAAC (Aluminium Alloy Conductor) Power Cable, Armoured Cable, SWA (Steel Wire Armoured) Cable.
Power cables are mainly used for power transmission and distribution systems in the power industry and general industries.
===Wires and cables for electrical equipment===
Rubber Insulated Cable, Mining, Drilling & Tunnelling Cable, Ship Cable, Nylon Sheathed Wire, Plastic Insulated Control Cable.
Electrical Equipment Cables are mainly used to supply and distribute electricity.
===Aerial Cable===
Aerial Bundled Cable, Copper Stranded Wire, Aluminium Conductor Steel Reinforced (ACSR) Wires, Aluminium Alloy Conductors (AAAC), Aluminium Stranded Conductor (AAC).
These cables are mainly used as overhead power lines for power transmission and power distribution.
===Special Cables and Wires===
Fire Resistant Cable, High Temperature Resistant Cable, Rodent Resistant Cable / Termite Resistant Cable, Waterproof Cable, Eco-friendly Direct Current cable, Medium Voltage Power Cable for Subway and Light-weight, Wind Energy Cable, 1E Class Nuclear Cable, Energy Efficient ACSR, UHV Supporting and Expanding Overhead Wires, Flexible Fire-proof Cable for 0.6/1KV.