Basic Info.
Conductor Type
Solid & Stranded
Application
Power Distribution Networks
Conductor Material
Aluminum Alloy Conductor
Range of Application
Power Distribution Networks
Armoured Layer
Steel Wire Armoured
Product Description
APPLICATIONYJLHV32-Aluminum Alloy Conductor XLPE Insulated Steel Wire Armoured PVC Sheathed Power Cable.This product is suitable for using in power distribution networks or fixed installations for industrial equipments with rated voltage up to and including 26/35KV BASIC INFORMATION1. Code Name YJLHV322. Rated Voltage (Uo/U)0.6/1KV3. Cable StructureAluminum Alloy Conductor/XLPE Insulation/PVC Inner Sheath/Steel Wire Armoured/PVC Outer Sheath CONSTRUCTION1. ConductorNumber of conductors:2,3,4,5The conductors shall comply with the requirement given in IEC2. InsulationXLPE(Cross-linked Polyethylene) according to IEC3. Armoured LayerSteel Wire Armoured CABLE STANDARDSGB/T12706-2008,IEC,BS,ASTM and etc. upon request. CHARACTERISTICS1. Conductor temperatureMaximum conductor temperature in normal use: 90ºC2. Max.short-circuit temperatureMaximum shall not exceed 250ºC(5s Max,Duration)3. Installation temperatureAmbient temperature under installation shall not be below 0ºC4. Minimum bending radiusThe bending radius of cable: (D-Diameter of cable) -------------------------------------≥7D5. Outer SheathPVC(Polyethylene Chloride)according to IECVoltage designationThe rated voltage of the cable for a given application shall be suitable for the operating conditions in the system in which the cable is used,and is expressed in the form of Uo/ U(Um)kV.Where:Uo-The rated power-frequency voltage between conductor and screen or metallic-sheath,for which the cable designed;U-The rated power-frequency voltage between conductors, for which the cable designed:Urn-The maximum value of the "hight system voltage " for which the equipment may he operated. Rated voltaged of cable applied in three phrase system are given in tableUUmUoFirst classSecond class11.20.60.633.61.83.667.23.66101268.71517.58.7122024121835422126Note:The first class cable suitable for one single-phrase earth-fault time does not exceed 1 min each time and Max. time not exceed 8 hours.and not exceed 125 hours in all in one year.The second class cable suitable fir more earth-fault time and more better insulation performance. Production Range of cableTypeNo. of coresNominal Cross sectional area m2Aluminum alloy conductorYJLHV3224-30034-63044-5003+14-63054-5004+14-5003+24-500*The armoured single-core cables are used for D.C system only. As for A.C system non-magnetic armoured material should be used. Or magnetic isolation measures should be applied. DIMENSIONS-YJLHV32-Table 01Nominal cross sectional area of conductor(mm²)Nominal insulation thickness(mm)YJLHV32Approx overall diameter(mm)Cable weight max(kg/km)2×100.720.97832×160.723.09202×250.926.411562×350.928.713282×50*1.025.412312×70*1.129.417332×95*1.132.420222×120*1.235.023282×150*1.448.237992×185*1.652.443052×240*1.757.851242×300*1.863.56408*Compacted conductorDIMENSIONS-YJLHV32 -Table 02Nominal cross sectional area of conductor(mm²)Nominal insulation thickness(mm)YJLHV32Approx overall diameter(mm)Cable weight max(kg/km)3×100.731.78563×160.724.010173×250.927.712963×350.930.215043×50*1.029.715923×70*1.134.622153×95*1.138.126413×120*1.245.233273×150*1.451.144523×185*1.655.851033×240*1.761.861063×300*1.867.371773×400*2.077.09692*Compacted conductor DIMENSIONS-YJLHV32 -Table 03Nominal cross sectional area of conductor(mm²)Nominal insulation thickness(mm)YJLHV32Approx overall diameter(mm)Cable weight max(kg/km)4×100.723.39604×160.725.711534×250.929.914874×350.932.917554×50*1.033.020974×70*1.138.726924×95*1.142.732214×120*1.249.844924×150*1.456.353334×185*1.661.361034×240*1.768.173684×300*1.874.583684×400*2.085.111732*Compacted conductor DIMENSIONS-YJLHV32 -Table 04Nominal cross sectional area of conductor(mm²)Nominal insulation thickness(mm)YJLHV32Approx overall diameter(mm)Cable weight max(kg/km)5×100.724.710715×160.727.612965×250.932.417045×350.936.522585×50*1.039.426205×70*1.144.632445×95*1.150.844795×120*1.255.752655×150*1.461.562415×185*1.667.271885×240*1.774.887035×300*1.883.2113325×400*2.093.613889*Compacted conductor DIMENSIONS-YJLHV32-Table 05Nominal cross sectional area of conductor(mm²)No.of coresNominal insulation thickness(mm)YJLHV32Approx overall diameter(mm)Cable weight max(kg/km)3*10+1*630.722.49.710.73x16+1x1030.725.0110110.73x25+1x1630.928.8139810.73x35+1x1630.931.0159910.73x50+1x253*1.032.0180510.93x70+1x353*1.138.5257410.93x95+1x503*1.142.7304911.03x120+1x703*1.248.5415111.13x150+1x703*1.452.5475811.13x185+1x953*1.657.4549111.13x240+1x1203*1.763.4657311.23x300+1x1503*1.869.6779911.43x400+1x1853*2.079.2990611.6*Compacted conductorDIMENSIONS-YJLHV32 -Table 06-ANominal cross sectional area of conductor(mm²)No.of coresNominal insulation thickness(mm)YJLHV32Approx overall diameter(mm)Cable weight max(kg/km)4x10+1*640.724.0102310.74x16+1x1040.727.0125110.74x25+1x1640.931.5162410.74x35+1x1640.933.9186310.7*Compacted conductorDIMENSIONS-YJLHV32 -Table 06-BNominal cross sectional area of conductor(mm²)No.of coresNominal insulation thickness(mm)YJLHV32Approx overall diameter(mm)Cable weight max(kg/km)4x50+1x254*1.038.3248210.94x70+1x354*1.142.9303610.94x95+1x504*1.149.0120111.04x120+1x704*1.253.5491411.14x150+1x704*1.458.2569411.14x185+1x954*1.663.9660611.14x240+1x1204*1.770.9797211.24x300+1x1504*1.879.11047411.44x400+1x1854*2.088.51264411.6*Compacted conductorDIMENSIONS-YJLHV32 -Table 07-ANominal cross sectional area of conductor(mm²)No.of coresNominal insulation thickness(mm)YJLHV32Approx overall diameter(mm)Cable weight max(kg/km)3x10+2x630.723.397620.73x16+2x1030.726.4120520.73x25+2x1630.930.3153120.73x35+2x1630.932.4172220.73x50+2x253*1.036.5230220.93x70+2x353*1.140.9281220.93x95+2x503*1.146.9390421.03x120+2x703*1.251.5460121.13x150+2x703*1.455.4521621.1*Compacted conductorDIMENSIONS-YJLHV32 -Table 07-B3x185+2x953*1.660.7607021.13x240+2x1203*1.767.1726521.23x300+2x1503*1.873.7864721.43x400+2x1853*2.083.81150821.6*Compacted conductor Product Data Of CableNominal cross-sectional area of conductor(mm²)Max.D.C resistance of conductor at 20ºC(Ω/km)Aluminum Alloy47.1964.48102.99161.85251.17350.843500.622700.430950.3111200.2461500.2001850.1592400.1213000.09714000.07555000.05876300.04558000.0356Power frequency A.C. Voltage testTest voltage 3.5kV/5 min Current carrying capacity of cableIn the air ConductorNominal Cross sectional area of conductor mm2Armored cableSingle CoreTwo CoreThree cores&Five cores Aluminum Alloy Conductor43242--64256--1055725850167193756425941201008635115150120105501401801451257018023019016595220285235200120260330270235150300380310270185350445355310240414530-365300485615-420400570720-495500670850--6307901000--8009201180-- Current carrying capacity of cableIn the groundConductorNominal Cross sectional area of conductor mm2Armored cableSingle CoreTwo CoreThere coresFive cores Aluminum alloyConductor4434747406566061501071757765169197105852511512513011035140150155130501651751851557020521523019095245260275230120280295315260150315335355295185360380400335240420445-390300475505-440400545575-505500620665--630705760--800800875-- Installation and Operation Condition of CableIn the air1.The distance between two adjacent cable' axle centers of single-core cables laid in parallel cross-section area of conductor≤185mm²;2 times of the cable diameter cross-sectional area of conductor≥240mm²;90mm2.Ambient air temperature:30ºC.3.Max.continous operating temperature of conductor: 90ºC. Current carrying rating factors for different ambient air temperatureAmbient air temperature20ºC25ºC30ºC35ºC40ºC45ºCCorrection factor1.091.041.000.950.900.84Directly in the ground1.The single-core cables are installed separately.The distance between the cablecenter is 2 times of the cable Diameter.2.Soil temperature: 25ºC.3.Max.continous operating temperature ofconductor: 90ºC.4.Thermal resistivity of soil : 1.0 ºC. m/W5.Depth of Direct-Buried:0.7m.Current carrying rating factors for different soil temperatureSoil temperature20ºC25ºC30ºC35ºC40ºCCorrection factor1.041.00.960.920.87
Address:
Room1116, Floor 11, Hongxing Jiuzhou International Plaza, Xincheng Road, Yixing, Wuxi, Jiangsu, China
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Chemicals, Electrical & Electronics, Service
Management System Certification:
ISO 9001, ISO 9000, ISO 14001, ISO 14000, ISO 20000, OHSAS/ OHSMS 18001
Company Introduction:
Established in 2014 and bringing together the factory more than 30 years of experience in cable, Lonheo is backed by the excellent reputation of our cooperated factory, All what we do is to make them as leading cable contractors in the world.
Lonheo is able to strive in today′s competitive business environment by creating synergy and consolidating the resources of all partners. This ensures that Lonheo remains operationally and financially strong.
With this strategic partnership in place, Lonheo is able to help our customers achieve their goals and provide greater value-added services to them.
Our company are focus on cable & wire supplyment and waste water treatment chemicals.
Our Features Product:
===Power Cables===
Ultra High Voltage, Power Cable, High Voltage Power Cable, Medium Voltage Power Cable, Low Voltage Power Cable, LSZH (low smoke zero halogen) Cable, XLPE Cable, AAAC (Aluminium Alloy Conductor) Power Cable, Armoured Cable, SWA (Steel Wire Armoured) Cable.
Power cables are mainly used for power transmission and distribution systems in the power industry and general industries.
===Wires and cables for electrical equipment===
Rubber Insulated Cable, Mining, Drilling & Tunnelling Cable, Ship Cable, Nylon Sheathed Wire, Plastic Insulated Control Cable.
Electrical Equipment Cables are mainly used to supply and distribute electricity.
===Aerial Cable===
Aerial Bundled Cable, Copper Stranded Wire, Aluminium Conductor Steel Reinforced (ACSR) Wires, Aluminium Alloy Conductors (AAAC), Aluminium Stranded Conductor (AAC).
These cables are mainly used as overhead power lines for power transmission and power distribution.
===Special Cables and Wires===
Fire Resistant Cable, High Temperature Resistant Cable, Rodent Resistant Cable / Termite Resistant Cable, Waterproof Cable, Eco-friendly Direct Current cable, Medium Voltage Power Cable for Subway and Light-weight, Wind Energy Cable, 1E Class Nuclear Cable, Energy Efficient ACSR, UHV Supporting and Expanding Overhead Wires, Flexible Fire-proof Cable for 0.6/1KV.